DEFINITIONS AND NOTES

TO46 ] TO39 (TO5) ] TO37 ] TO8 ] TO66 ] TO822 ] TO3 ] Butterfly ] TOSA ] HHL ] CCD ] FPA ] Select Assistant ] Reliability ] How to Select ] Options ] [ Definitions ] DataSheets ]

 

Parameter Description Notes
DTmax

Maximum temperature difference provided by TEC sub-mount at I=Imax 

DTmax rated at Qmax=0, at other Q the DT should be estimated as DT=DTmax(1-Q/Qmax)

Qmax

Maximum heat pumping capacity provided by TEC sub-mount at I=Imax 

Qmax rated at DT=0, at other DT cooling capacity should be estimated as Q=Qmax(1-DT/DTmax)

Imax

Electric current resulting in greatest DTmax

 

Umax

Voltage drop at DTmax

 

Rt

Thermal resistance of the sub-mount package to the heat that is rejected at TEC operation

 

Th

TEC sub-mount bottom side temperature

Performance data shown in specifications (DTmax, Qmax, Imax, Umax) are given for Th=300K

H

Total TEC height

All dimensions are given in mm. 
Dimensions A is perpendicular to TEC electric wire direction (See drawings at specifications).

A x B

Cold side dimensions

 

 
 

TE Modules ] Sub-Mounts ] Software ] Devices ] Components ]
TO46 ] TO39 (TO5) ] TO37 ] TO8 ] TO66 ] TO822 ] TO3 ] Butterfly ] TOSA ] HHL ] CCD ] FPA ] Select Assistant ] Reliability ] How to Select ] Options ] [ Definitions ] DataSheets ]

Send mail to RMT Ltd  with questions or comments about this web site.
Copyright © 2003-2010 RMT Ltd.

Last Updated:  Thursday, May 06, 2010

frontpag.gif (9866 bytes)